Design Ethernet

netX 50/100/500 have two integrated Physical Layer Units (PHYs) for Ethernet Communication, that allow to build systems with two Ethernet ports, while using only a few external components like pull-ups and transformer(s).

The PHYs can be operated in two basic modes, which are twisted pair (10BASE-T / 100BASE-TX) and fiberoptic  mode (100BASE-FX).

Twisted Pair

For 10BASE-T or 100BASE-TX  Ethernet communication, the PHYs must be connected as shown in the following example schematic:

 

Component

Value

Tolerance

Rating

 

 

 

 

R1a, R1b, R2a, R2b, R4a, R4b, R5a, R5b

50 Ohm

1%

1/8 W

R3a, R3b

10 Ohm

1%

1/16 W

R7a, R7b, R8a, R8b, R9a, R9b, R10a, R10b

75 Ohm

1%

1/16 W

R11

12.4 kOhm

1%

1/16 W

 

 

 

 

C1a, C1b, C2a, C2b

10nF

20%

 

C3a, C3b

10nF

-

2 kV

C4a, C4b, C5a, C5b, C6, C8

100nF

-

6.3V

C7, C9

10uF

-

6.3V

 

 

 

 

L1, L2

1000 Ohm @100 MHz

-

200 mA

 

 

 

 

H1, H2

H1102, HX1188 (Pulse Eng.),

TS6121C (Bothhand)

 

 

 

Fiberoptic

For 100BASE-FX Ethernet communication, the netX requires external transceivers. Since these transceivers usually work with LVPECL (Low Voltage Positive Emitter Coupled Logic) levels, appropriate signal converters must further be connected between netX and transceivers. The signal converters should be placed as close as possible to the corresponding netX pins and the traces of the differential signal lines between buffers and transceivers should provide an impedance of 50 Ohm (100 Ohm differential impedance). The signal lines are to be terminated with a Thevenin termination as shown in the following schematics.

 

Component

Value

Tolerance

Rating

 

 

 

 

R1a, R1b, R2a, R2b, R3a, R3b, R4a, R4b, R5a, R5b

127 / 130 Ohm

1%

 

R6a, R6b, R7a, R7b, R8a, R8b, R9a, R9b, R10a, R10b

82.5 / 82 Ohm

1%

 

R11

12.4 kOhm

1%

1/8 W

R12

1k / 82 Ohm

 

 

R13

1.6k  / 130 Ohm

 

 

 

 

 

 

C6, C8

100nF

-

6.3V

C7, C9

10uF

-

6.3V

 

 

 

 

L1, L2

1000 Ohm @100 MHz

-

200 mA

 

Ethernet PHYs unused

If the internal Ethernet PHYs are not used in a netX design, the signal pins (RXP/RXN, TXP/TXN) should simply be left open. However, all power supply pins must still be connected, as well as the reference resistor, as shown on the following schematics: